Ground Floor Flat Damp Survey in Anerley (SE20)

Back to all Case Studies
Ground Floor Flat Damp Survey in Anerley (SE20)

A Level 3 damp survey was conducted on a ground-floor flat in Anerley (SE20). The property owner instructed an independent damp specialist to evaluate visible wall dampness and determine necessary building repairs. The assessment provided a professional, unbiased report free from contractor sales pressure.

About the Issue

Floor-to-ceiling dampness in the bedroom, low-level blistering plaster in the kitchen/dining area and damp staining near the bathroom window prompted concern for the homeowner. They sought expert verification to isolate active leaks and establish whether structural timber rot was present.

The Challenge

Executing the Level 3 damp survey involved inspecting all internal rooms, scanning walls with thermal cameras, measuring environmental parameters, testing subfloor ventilation and inspecting the roof via drone.

The diagnostic process provided concrete factual findings:

  • Air humidity testing registered 59.3% relative humidity at an ambient temperature of 19.7°C.
  • Thermal imaging verified floor-to-ceiling moisture across two bedroom walls.
  • Calibrated moisture meters confirmed low-level rising damp along three exterior walls in the kitchen and dining area, linked to an absent visible DPC and a defective external render plinth below the kitchen window.
  • Inspection of the bathroom identified a suspected bath overflow leak contributing to moisture around the bathroom window.
  • Drone checks confirmed the roof was watertight, extractor fans operated properly and structural timbers were sound with zero dry rot, wet rot, or woodworm.

The diagnostic evidence proved that low-level rising damp and localised thermal loss were affecting the flat, while the core building structure remained sound.

The Solution

The report detailed an actionable remedial strategy fixed at £4,200 + VAT:

  • Remove plaster to full height on two bedroom walls and fit a thermal board insulation system.
  • Hack off plaster to 1.4 metres high on three exterior kitchen/dining walls, inject a chemical DPC, apply salt neutraliser, two coats of tanking slurry, two coats of Sika waterproof render and replaster to a smooth finish.
  • Smooth and repair the external render plinth under the kitchen window and fit one external air vent to boost subfloor airflow.
  • Repair the bath overflow leak in the bathroom.
  • Temporarily detach and reinstate electrical back boxes, switches and radiators in work zones.

The Outcome

The survey provided the homeowner with total peace of mind regarding the flat’s structural integrity. Armed with an independent diagnostic report and a fixed quote, they avoided over-engineered quotes and directed the budget strictly into essential damp proofing and thermal upgrades.

Why This Case Matters

Defective external render plinths can bridge damp proof courses and allow ground moisture to penetrate internal kitchen walls. Independent damp specialists evaluate external ground-level details alongside internal masonry, ensuring external defects are repaired alongside internal tanking.

FAQs
What relative humidity was recorded inside the kitchen?

Environmental testing recorded relative humidity at 52.5% throughout the property, which is well within normal residential limits and rules out condensation issues.

Are internal wall tanking or chemical DPC injections required?

No. The dampness was solely penetrating damp from external defects; fixing the staircase membrane and chimney caps will resolve the problem without internal chemical treatments.

How was the condition of the main roof verified?

An aerial drone inspection was conducted, revealing that the main roof was generally sound, but the chimney caps were defective or missing, allowing rainwater to enter.

Gain complete confidence in your building’s health with an independent diagnostic survey.

Damp Survey Costs

Transparent pricing with no hidden fees for our independent, unbiased surveys.

Level 1

Level 1

£199 + VAT

What’s included:

  • Inspection of walls
  • Inspection of floors
  • Inspection of ceilings
  • Leak inspection of drains and plumbing
  • Damp information and prevention guide
Level 2

Level 2

£299 + VAT

What’s included:

  • Everything in Level 1
  • Dry rot inspection
  • Wet rot inspection
  • Woodworm inspection
  • Damp information and prevention guide

 Survey Add Ons

Add On 1

£299 + VAT
Lab Analysis Of Plaster

Laboratory analysis Of plaster identifies hygroscopic salts such as chlorides and nitrates. which indicate whether damp is caused by rising groundwater or by plumbing leaks, This testing removes guesswork, allowing the exact source of moisture to be identified so the correct treatment is applied rather than carrying out unnecessary damp-proofing work.

Add to Survey

Add On 2

£299 + VAT
Mould Lab Swab Testing, qPCR on DNA

qPCR DNA mould testing detects microscopic mould spores that are invisible during a normal inspection and van remain hidden behind walls, floors. or inside building rkaterials. It identifies the exact mould species present and the contamination level, allowing hidden mould problems to be confirrned and properly treated before they affect the property or occupants’ health.

Add to Survey

Qualifications: All our surveyors are PCA and CSRT qualified for remedial treatments and also CSSW qualified for structural waterproofing.
Next day report: You will receive the report within 24 hours of the inspection taking place.

These are the tools we use

Damp Meter

Damp Meter

A damp meter is a diagnostic tool used to detect and measure moisture levels within building materials such as plaster, brick, timber, and concrete.

Borescope camera

Borescope camera

borescope camera is a small inspection camera attached to a flexible semi-rigid cable that allows you to see inside areas that are otherwise inaccessible.

Drone Inspection

Drone Inspection

A drone is a remotely operated aerial device equipped with a camera that allows visual inspection from above without the need for scaffolding or ladder.

Air Humidity Sensor

Air Humidity Sensor

Air humidity sensor measures the amount of moisture present in the air, expressed as relative humidity (RH) in percentage. It helps determine whether indoor conditions are contributing to condensation, mould growth, or damp-related issues.

Thermal Imaging Camera

Thermal Imaging Camera

A thermal imaging camera detects temperature differences on surfaces by using infrared technology to produce a heat map image. In damp investigations, it helps identify cold spots, moisture intrusion, insulation defects, thermal bridging and leaks.

Air Flow Ventilation Detector

Air Flow Ventilation Detector

An air flow ventilation detector measures the movement and volume of air passing through vents, extractor fans, and air bricks. It confirms whether ventilation systems are working properly and achieving adequate air changes within a room. Poor airflow leads to trapped moisture, high humidity, condensation on cold surfaces, and ultimately mould growth.

Mould Lab Swab Testing

Mould Lab Swab Testing

A mould swab test is carried out to confirm the presence of hidden mould growth and identify the specific species involved. Surface mould is not always visible, especially behind furniture, inside cavities, or within ventilation systems. Laboratory analysis of a swab sample determines whether active mould spores are present and what type they are, which helps assess potential health risks and decide the correct remediation approach rather than relying on visual assumption alone.

Lab Analysis of Plaster

Lab Analysis of Plaster

Laboratory analysis of plaster is used to identify the type of salts present within the material, typically chlorides and nitrates. The presence and concentration of these salts help determine whether the moisture source is consistent with rising damp, ground contamination, or another forms [sic] of water ingress. such as mains water leak, This removes guesswork and prevents misdiagnosis, ensuring the correct remedial treatment is specified rather than applying unnecessary or ineffective solutions.

 

Professional Damp Diagnostic Equipment

Surface Damp Meter

Purpose:

Takes comparative surface moisture readings across accessible walls, floors, ceilings, and building joinery.

Common Uses / Notes:

Maps surface moisture profiles to help identify rising damp, penetrating damp, condensation, or active plumbing leaks.

Deep-Penetration Damp Meter

Purpose:

Detects moisture changes deep below the immediate surface of structural materials without destruction.

Common Uses / Notes:

Evaluates dampness within wall cores, beneath floorboards, inside subfloors, and behind finishes without removing plaster.

Non-Invasive Moisture Scanner

Purpose:

Scans surface planes non-invasively without inserting pins or probes into decorated finishes.

Common Uses / Notes:

Checks decorated walls, tiled surfaces, and delicate floor coverings to trace sub-surface water migration non-destructively.

HD Borescope Inspection Camera

Purpose:

Provides high-definition visual examination inside enclosed, narrow, or inaccessible building cavities.

Common Uses / Notes:

Inspects subfloor voids, wall cavities, dry lining, and enclosed pipework to locate leaks and defects with minimal disruption.

4K Inspection Drone

Purpose:

Captures high-resolution imagery and video of high-level external structures and rooflines.

Common Uses / Notes:

Inspects roof tiles, chimney stacks, lead flashing, parapet walls, valleys, and gutters to locate water ingress sources.

Air Humidity Sensor

Purpose:

Measures ambient air temperature and relative humidity (%RH) levels within living areas.

Common Uses / Notes:

Determines whether atmospheric moisture, cold bridging, or insufficient ventilation supports surface condensation and mould growth.

Thermal Imaging Camera

Purpose:

Visualises surface temperature differentials across walls, ceilings, and floors.

Common Uses / Notes:

Detects cold spots, missing insulation, thermal bridges, evaporative cooling zones, and concealed water leaks.

Airflow & Ventilation Detector

Purpose:

Measures volumetric air extraction performance (L/s or m3/h) of mechanical extractor fans.

Common Uses / Notes:

Tests kitchen, bathroom, and utility fans to verify compliance with UK Building Regulations Part F and control condensation

Gas Screening Instrument

Purpose:

Screens indoor environments for sewer gas intrusion, combustible gases, and combustion concerns.

Common Uses / Notes:

Traces foul odours, soil stack leaks, and sewer gases (H2S, NH3, CH4, CO, O2). Does not replace Gas Safe registered safety checks.

Chemical Vapour Detector

Purpose:

Screens air for Volatile Organic Compounds (TVOC/VOC) and chemical substances like formaldehyde (HCHO).

Common Uses / Notes:

Investigates unexplained chemical odours, building material off-gassing, post-flood air safety, and indoor air quality.

Airborne Particle Detector

Purpose:

Measures airborne particulate concentrations across precise micron size ranges (PM1.0, PM2.5, PM10).

Common Uses / Notes:

Assesses fine dust, smoke, airborne matter, and environmental air quality following water damage or mould outbreaks.

Electrical Socket & RCD Tester

Purpose:

Provides basic safety and protective circuit screening in areas affected by dampness.

Common Uses / Notes:

Identifies socket wiring faults, tests RCD trip functions, and checks AC voltage in wet areas. Does not replace an EICR.

Equipment & Inspection Levels

Select Your Survey

Level 1

Standard Damp Inspection

Standard price: £299 + VAT

Special offer: £199 + VAT (Limited Time Offer)

Offer ends in--Days--Hours--Mins--Secs

Level 1 is intended for customers with a relatively uncomplicated damp concern who require an inspection of accessible internal areas.

Survey equipment

  • Electronic damp meter

Included checks

  • Accessible wall surfaces
  • Accessible flooring
  • Ceilings
  • Visible drains and plumbing for evidence of leaks
  • Damp-prevention and information guide

Recommended for

This option is appropriate for a suspected rising-damp area, visible staining, an isolated patch or a general check using a standard moisture meter.

It does not include deep-material scanning, non-invasive subfloor moisture investigation, timber-decay checks or the advanced equipment provided under Levels 2 and 3.

Level 2

Detailed Damp & Timber Survey

Standard price: £399 + VAT

Special offer: £299 + VAT (Limited Time Offer)

Offer ends in--Days--Hours--Mins--Secs

Level 2 expands the basic inspection by including specialist moisture equipment and checks for timber deterioration.

Survey equipment

  • Electronic damp meter
  • Deep-reading moisture meter
  • Non-invasive scanner

Included checks

  • Walls, flooring and ceilings
  • Visible plumbing and drainage leaks
  • Dry-rot inspection
  • Wet-rot inspection
  • Woodworm inspection
  • General timber assessment
  • Deeper readings within suitable materials
  • Non-invasive testing beneath accessible flooring and within accessible subfloor areas
  • Damp-prevention and information guide

Recommended for

Level 2 is suitable when the damp may extend beyond the surface or where timber decay is suspected.

The deeper and non-invasive equipment may detect patterns within walls, beneath flooring and behind suitable finishes without unnecessary dismantling.

Homebuyers and vendors often select Level 2 when they require more information than a basic damp-meter inspection but do not need the high-level external and environmental checks provided with Level 3.

Specialised Laboratory Testing Add-Ons

Add-On 1

Laboratory Analysis of Plaster Samples

Price £299 + VAT

Small plaster samples are carefully taken from affected walls and submitted to an independent laboratory for salt analysis. The laboratory tests for the presence and precise concentration of hygroscopic salts, including nitrates and chlorides.

Diagnostic Value: Soluble ground salts are drawn up through masonry during rising damp and remain in plaster permanently. Salt analysis scientifically differentiates true rising damp from condensation or historic leak contamination.

Note: Plaster sampling requires minor material removal and is our only add-on involving minor invasive work.

Add-On 2

Mould Laboratory Testing & qPCR DNA Analysis

Price £299 + VAT

Surface swab or lift samples are submitted to an accredited laboratory for advanced qPCR DNA analysis.

Diagnostic Value: Accurately identifies exact mould species, measures contamination concentrations, and detects hidden fungal growth inside cupboards or behind dry lining. Delivers impartial scientific evidence to guide safe environmental remediation.

The service may be valuable where:

  • A musty odour exists without obvious growth
  • Previous leaks or flooding may have caused hidden contamination
  • Mould is suspected behind furniture
  • Cupboards or concealed areas smell damp
  • Growth continues returning after cleaning
  • The visible extent appears uncertain
  • Independent laboratory evidence is required

Note: The findings may help establish whether the sampled contamination is relatively minor or potentially part of a wider moisture problem. Results apply to the sampled areas and do not automatically represent every room or concealed part of the building. Laboratory information is combined with inspection findings to help explain the extent and likely moisture source.

Add-On 3

Gas, Chemical Vapour & Airborne Particle Testing

Price £299 + VAT

Comprehensive environmental air quality and gas screening tailored to specific property concerns.

Screening Suite Includes:

  • General indoor-air-quality screening
  • TVOC and VOC measurement
  • HCHO/formaldehyde screening
  • PM1.0 fine-particle readings
  • PM2.5 fine-particle readings
  • PM10 particle readings
  • Dust and smoke assessment
  • H₂S, NH₃ and
  • CH₄ sewer-gas indicators
  • CH₄ and C₃H₈ combustible-gas screening
  • CO monitoring
  • Hydrogen sulphide measurement
  • Ammonia screening
  • Oxygen-level measurement
  • Stale-air and ventilation checks
  • Drain-smell investigation
  • Chemical-odour assessment
  • Conditions following leaks or flooding
  • Preliminary combustion-gas screening
  • Building-product off-gassing check
  • Airborne pollutant screening

Diagnostic Value: Identifies hidden airborne pollutants, drain odours, chemical off-gassing, and stale air problems.

Note: Indoor environmental problems sometimes continue after the visible water has dried. Damp materials, stagnant water, contaminated drains, chemicals and damaged finishes can create smells or release airborne substances that cannot be assessed visually.

The equipment may help narrow down whether an unpleasant odour is associated with drains, sewer gases, damp materials, chemical vapours or insufficient fresh-air movement. It can also record airborne fine particles after flooding, leakage or building work.

This is a screening-level assessment and should not be confused with full laboratory air analysis. It does not replace emergency procedures, gas-appliance servicing or specialist environmental-health testing.